Below we’ve listed the answers to some of the most common questions we hear about digital imaging. If you don’t see what you need, feel free to ask us a question on our Facebook fan page.

How does DR Digital work?

Direct digital radiography (DR) is based on CCD (Charge Couple Device) technology, but it is much faster. Like CCD, DR systems rely on a phosphor-like material, also known as a scintillator, to capture the x-rays. Rather than forming a latent image, DR images light up immediately. An extremely sensitive camera, more like the Hubble space telescope than your digital camera, records the light, digitizes it and sends it to the computer in seconds.

Why Choose DR over CR digital technology?

  1. Workflow
  2. Durability
  3. Image Quality

1. Workflow

The difference is workflow. The workflow for CR is very similar to traditional film x-rays. To take a CR image, you must load a cassette, take it to the patient, expose the film, remove the film, return film to the processor and wait for the image to appear. CR processing is actually a bit slower than film processing. Many practitioners cite the slower workflow as a reason for choosing DR over CR technology.

DR workflow is completely different. Rather than the 6 steps mentioned above, the DR workflow only requires patient positioning, exposure, and viewing the film on the computer. Veterinarians don’t need to let go of the patient to take an x-ray.

2. Durability

CR systems are fairly reliable, but their mechanical systems are very sensitive to contamination in a veterinary practice.

The most common and costly item to replace is the PSP plate that the CR system uses to capture the x-ray flux. These plates are especially sensitive to contamination from animal hair, meaning their lifespan is even shorter for veterinarians. Replacement plates cost roughly $1,000 each. CR systems also rely on a plate reader that moves a scanning laser across the PSP plate. Precision is very important to accurate image collection and clogging of the reader is a common cause for service calls.

DR systems have no moving parts other than a cooling fan, which rarely comes into contact with patient or user. DR systems do rely heavily on a computer. Like all computers, data should be backed up regularly to avoid data loss.

3. Image Quality

In general, DR systems offer greater bit of depth, digitzing the image at 14 bits (16,384 shades of grey) or more. CR is often limited to 10 bits (1,024 shades of grey).

What is DICOM?

DICOM (or Digital Imaging and Communications in Medicine) is a standard developed by the American College of Radiology and the National Electrical Manufacturers Association. The standard was established to meet the needs of manufacturers and users in the medical imaging equipment for the exchange of data on standard networks. Already accepted across all medical fields, DICOM simplifies the development for all types of medical imaging. “DICOM-compatibility” simply means that different users of different imaging devices will be able to smoothly exchange information. (More info at http://medical.nema.org)

What is a PACS system?

PACS (or Picture Archive and Communications System) is used by the radiology and diagnostic imaging industry to manage information and images electronically. The system is responsible for acquiring, transmitting, storing, retrieving, and displaying digital images and related patient information from a variety of imaging sources, and communicating the information over a network.

Do I need a PACS system?

This will depend on your clinic set-up. If you have a multi-doctor clinic with multiple viewing stations, it is best to have a PACS environment. Not only will the PACS help manage all of the patients’ files for the multiple doctors, it will also act as your image storage facility.

Do I need additional networking brought in my X-ray room?

You will need a network connection in your x-ray room for the “acquisition station” computer. This computer needs to be networked into the “Virtual Viewbox” workstation computer. This can be done as an independent connection that does not link in with any other networking or it can be linked in with an existing network. The main goal is for the two computers to communicate without interruption.

What about x-ray dose with digital imaging?

Digital images shown on many comparisons may appear to be excellent, but the dose used to create the image should be considered. In many cases the dose is outside of normal levels. In an image quality comparison by an independent reporting service, the InnoVet’s CCD receptor had one of the lowest dose requirements in the industry. With the Versa DR, you do not need an excessive dose to obtain a quality image.